  dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 1 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation 6w,ultra wide input, isolated & regulated dual/single output, ymd package, dc-dc converter patent protection rohs features z wide range of input voltage (4:1) z efficiency up t o 88% z no-load power consumption as low as 0.2w z isolation voltage :1500vdc z operating temperature range: -40 to +85 z input under-voltage protection, output over-voltage, over-current, short circuit protection z meet cispr22/en55022 class a z international standard pin-out z a2s (wring mounting) and a4s (35mm rail mounting) products featuring anti-reverse connection for input ura_ymd-6wr3 & urb_ymd-6wr3 series products are of 6w output power, extremely wide range of voltage input of 9-36vdc, 18-75vdc, isolation voltage of 1500vdc, output over-voltage protection and output short circuit protection with the bare component in compliance with cispr22/en55022 class a; these products are widely used in fields such as medical care, industrial control, electric power, instruments and communication. selection guide part no. input voltage (vdc) output efficiency (%,min./typ.) @fullload max. capacitive load ( f) nominal (range) max. output voltage (vdc) output current (ma) (max./min.) ura2405ymd-6wr3 24 (9-36) 40 5 600/30 81/83 470 ura2412ymd-6wr3 12 250/12 85/87 100 ura2415ymd-6wr3 15 200/10 86/88 100 ura2424ymd-6wr3 24 125/6 86/88 100 urb2403ymd-6wr3 3.3 1500/75 77/79 1800 URB2405YMD-6WR3 5 1200/60 81/83 1000 urb2409ymd-6wr3 9 667/33 83/85 680 urb2412ymd-6wr3 12 500/25 85/87 470 urb2415ymd-6wr3 15 400/20 86/88 220 urb2424ymd-6wr3 24 250/13 86/88 100 ura4805ymd-6wr3 48 (18-75) 80 5 600/30 81/83 470 ura4812ymd-6wr3 12 250/12 85/87 100 ura4815ymd-6wr3 15 200/10 86/88 100 ura4824ymd-6wr3 24 125/6 86/88 100 urb4803ymd-6wr3 3.3 1500/75 77/79 1800 urb4805ymd-6wr3 5 1200/60 81/83 1000 urb4812ymd-6wr3 12 500/25 85/87 470 urb4815ymd-6wr3 15 400/20 86/88 220 urb4824ymd-6wr3 24 250/13 86/88 100 notes 1 part no. with suffix of ?a2s? means chassis mounting and suffix of ?a4s? mea ns din-rail mounting (e.g. URB2405YMD-6WR3a2s means chassis mounting; URB2405YMD-6WR3a4s means din-rail mounting); 2 absolute maximum rating without damage on the converter, but it isn't recommended; 3 efficiency is measured in nominal input voltage and rated output load;a2s (w iring) and a4s (rail) model due to input reverse polarity protection, min imum efficiency greater than min.-2 is qualified. 4 the capacitive loads of positive and negative outputs are identical. input specifications it em op era ti n g c on diti ons mi n. typ . m ax. u n it
dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 2 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation in p ut current (full load / no-load) 24vdc in p ut -- 316/5 -- m a 4 8vdc in p ut -- 160/4 -- reflected ri pp le current 24vdc in p ut -- 20 -- 4 8vdc in p ut -- 20 -- in p ut im p ulse v olta g e(1sec.max.) 24vdc in p ut -0.7 -- 50 v dc 4 8vdc in p ut -0.7 -- 100 startin g v olta g e 24vdc in p ut -- -- 9 4 8vdc in p ut -- -- 18 under-volta g e t urn-off 24vdc in p ut 5.5 6.5 -- 48vdc input 14.0 15.5 -- in p ut filter pi filter output specifications item operating conditions min. typ. max. unit output voltage accuracy -- 1 3 % balance of output voltage dual output, balanced load -- 0.5 1.5 line voltage regulation full load, the input voltage is from low voltage to high voltage -- 0.2 0.5 load regulation 5%-100% load -- 0.5 1 cross regulation dual output, main circuit with 50% load, auxiliary circuit with 10%-100% load -- -- 5 transient recovery time 25%loadstepchange -- 300 500 s transient response deviation 3.3v, 5v, 5v output -- 5 8 % others -- 3 5 temperature drift coefficient full load -- -- 0.03 %/ ripple & noise* 20mhz bandwidth -- 60 85 mv p-p output over-voltage protection input voltage range 110 -- 160 %vo output over-current protection 110 140 190 %io output short circuit protection continuous, self-recovery note:*parallel line test method is adopted to test ripple and noise, please see dc-dc converter application notes for specific operation methods. general specifications item operating conditions min. typ. max. unit insulation voltage input-output, with the test time of 1 minute and the leak current lower than 1ma 1500 -- -- vdc insulation resistance input-output, insulation voltage 500vdc 1000 -- -- m isolation capacitance input-ou tput, 100khz/0.1v -- 1000 -- pf operating temperature derating if the temperature is 71 (see fig. 1) -40 -- 85 storage humidity without condensation 5 -- 95 % storage temperature -55 -- 125 max. operating temperature for casing within the operating temperature curve -- -- 105 lead temperature welding spot is 1.5mm away from the casing, 10 seconds -- -- 300 vibration 10-55hz, 10g, 30 min. along x, y and z switching frequency * pwm mode -- 300 -- khz mtbf mil-hdbk-217f@25 1000 -- -- k hours note:* this series of products using reduced frequency technology, the switching frequency is test value of full load,when the load is reduced to belo w50%,the switching frequency decreases with decreasing load. physical specifications casing material aluminum alloy
dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 3 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation package dimensions horizontal package 25.40*25.40*11.70 mm a2s chassis mounting 76.00*31.50*21.20 mm a4s din-rail mounting 76.00*31.50*25.80 mm weight horizontal package/a2s wiring package/a4s rail package 14g /36g /56g(typ.) cooling method free air convection emc specifications emi conducted disturbance cispr22/en55022 class a (bare component)/ class b (see fig.3- for recommended circuit) radiated emission cispr22/en55022 class a (bare component)/ class b (see fig.3- for recommended circuit) ems electrostatic discharge iec/en61000-4-2 contact 4kv perf. criteria b radiation immunity iec/en61000-4-3 10v/m perf. criteria a eft iec/en61000-4-4 2kv (see fig.3- for recommended circuit) perf. criteria b surge immunity iec/en61000-4-5 2kv (see fig.3- for recommended circuit) perf. criteria b conducted disturbance immunity iec/en61000-4-6 3 vr.m.s perf. criteria a immunities of voltage dip, drop and short interruption iec/en61000-4-29 0-70% perf. criteria b product characteristic curve operating temperature( )  t emperature derating curve output po we r pe rc e ntage( %) -40 040 71 85 120 80 60 100 120 40 20 0 safe operating area fig. 1 ura4815ymd- 6wr3 70 75 80 85 90 95 100 18 24 30 36 42 48 54 60 66 75 efficiency(%) input voltage(v) efficiency vs input voltage (full load) ura4815ymd- 6wr3 50 60 70 80 90 100 5 102030405060708090100 efficiency(%) output current percentage(%) efficiency vs output load(vin=vin-nominal) urb2405ymd- 6wr3 60 65 70 75 80 85 90 95 100 9 121518212427303336 efficiency(%) input voltage (v) efficiency vs input voltage (full load) urb2405ymd- 6wr3 50 60 70 80 90 100 5 10 20 30 40 50 60 70 80 90 100 efficiency(%) output current percentage (%) efficiency vs output load(vin=vin-nominal)
dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 4 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation design reference 1. typical application all the dc/dc converters of this series are tested according to the recommended circuit (see fig. 2) before delivery. if it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors cin and cout or select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product. dc dc vin gnd +vo 0v cin cout vin gnd +vo 0v cin cout dc dc -vo cout dual single fig. 2 vin(vdc) cin(uf) cout(uf) 24 100 10 48 10~47 10 2. emc solution-recommended circuit ldm1 c0 mov fuse c1 v in gnd + v in gnd +vo 0v dc/dc cy1 cy 2 c2 load fig. 3 notes: part in the fig. 3 is used for ems test and part for emi filtering; selected based on needs. parameter description model vin:24v vin:48v fuse choose according to actual input current mov s14k35 s14k60 c0 330 f/50v 330 f/100v c1 1 f/50v 1 f/100v c2 refer to the cout in fig.2 ldm1 4.7 h cy1, cy2 1nf/2kv emc solution-recommended circuit pcb layout fig. 4 note: the min. distance of the bonding pads between input & output isolation capacitors (cy1/cy2) shall be 2mm. 3. t he product does not support output in parallel w ith powe r pe r liter o r hot-plug use 4. for more information please find the app lication note on www.mornsun-power.com
dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 5 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation dimensions and recommended layout ura_ymd-6wr3a2s & urb_ym d-6wr3a2s dimensions
dc/dc powe r supply module ura_ymd-6wr3 & urb_ymd-6wr3 series 201 4 .07.17-a/0 page 6 of 6 mornsun guangzhou science & technology co., ltd. reserves the copyright and right of final interpretation ura_ymd-6wr3a4s & urb_ym d-6wr3a4s dimensions note: 1. packing information please refer t o 'product packing information'. packing bag number : 58210003(dip),58220022(a2s/a4s package); 2. recommended used in more than 5% load, if the load is lower than 5%, then the ripple index of the product may exceed the specification, but does not affect the reliability of the product. 3. the unbalance degree of the recommended dual output module load: 5%; if the degree exceeds 5%, then the product performances cannot be guaranteed to comply with all the perfor mance indicators in the manual, and please directly contact our technicians for specific information; 4 . the max. capacitive load should be t ested w ithin t he input v oltage range and under full load conditions; 5. unless otherwise specified, data in this datas heet should be tested under the conditions of ta=25 , humidity<75% when inputting nominal voltage and outputting rated load; 6. all index testing methods in this datasheet are based on our company?s corporate standards; 7. the performance indexes o f t he product models listed in t his datasheet are as above, but some indexes of non-standard model products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information; 8. we can provide product customization service; 9. specifications of this product are subject to changes without prior notice. mornsun guangzhou science & technology co., ltd. address: no. 5, kehui st. 1, kehui development center, science ave., guangzhou science city, luogang district, guangzhou, p. r. china tel: 86-20-38601850-8801 fax: 86-20-38601272 e-mail: info@mornsun.cn


▲Up To Search▲   

 
Price & Availability of URB2405YMD-6WR3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X